inline
sub-base
non”plug-in”
sub-base
non”plug-in”
sub-base with
pressure
regulators
sub-base with
pressure
regulators and
flow controls
stacking
Series
45
Individual mounting Series
Manifold mounting
Direct solenoid and solenoid pilot operated valves
EXH.
IN
A
B
65
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
SERIES FEATURES
• Single and double solenoid or remote air.
• The patented MACSOLENOID
®
for fastest possible response times.
• Bonded balanced poppets for high flow, precise repeatability, and consistent operation.
• Balanced poppet design permits versatility in pipping. Valves can be piped as 4-way, 3-way or 2-way,
normally closed or normally open or can be used for vacuum, diverter or selector applications.
• Use on lube or non-lube service.
• Extremely high cycle rates.
• Extremely long service life due to unique poppet cushions.
• Manual overrides as standard.
• Various solenoid enclosures and plug-in connectors
• Optional surge suppression available.
• Low wattage DC solenoids — down to 1.8 watts.
• Patented MACSOLENOID
®
— virtually burn-out proof on AC service.
Epoxy encapsulated
solenoid
Spring biased
moveable pole piece
Manual operator
Armature
Push pin
Bonded balanced poppets
Spring return
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
66
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
VALVE CONFIGURATIONS AVAILABLE
• 2-position single and double solenoid or remote air.
• Single pressure (4 or 5 ports)
• Individual, stacking and manifold base mounted models.
• Integral individual exhaust flow controls with common exhaust port.
• Integral regulators and flow controls on manifolds.
SPECIAL APPLICATIONS :
The balanced poppet design facilities using the same valve for many functions and can
be used for pressure, vacuum or plugged without the necessity of changing any parts.
Pipping suggestions are shown in the chart below.
BA
IN EXH
4-WAY
B-PLUGGED A
IN EXH
3-WAY
NORMALLY CLOSED
B A-PLUGGED
IN EXH
3-WAY
NORMALLY OPEN
B-PLUGGED A
IN EXH-PLUGGED
2-WAY
NORMALLY CLOSED
B A-PLUGGED
IN EXH-PLUGGED
2-WAY
NORMALLY OPEN
BA
IN EXH-PLUGGED
DIVERTER
X
X
XX X
B A-PLUGGED
IN
PRESS
OR
VAC
EXH
PRESS
OR
VAC
SELECTOR "A"
CAN BE USED AS
SELECTOR PORT
OUTLET IF DESIRED
X
X
X
Operator De-Energized
Operator Energized
67
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
Function Port size Flow (Max) Individual mounting Series
4/2 #10-32 - 1/8” 0.15 C
v
inline
1. Balanced poppet, immune to variations of
pressure.
2. Short stroke with high flow.
3. The patented solenoid develops high shifting
forces.
4. Powerful return spring.
5. Manual operator standard on all valves.
6. Burn-out proof solenoid on AC service.
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
Port size
1/8” NPTF
# 10-32 UNF
Single operator
45A-AA1-D
XXX-XXX
45A-AB1-D
XXX-XXX
Double operator
(Minimum DC wattage 5.4W)
45A-GA1-D
XXX-XXX
45A-GB1-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
Port size
1/8” NPTF
# 10-32 UNF
Single operator
45A-AA2-D
XXX-XXX
45A-AB2-D
XXX-XXX
Double operator
(Minimum DC wattage 5.4W)
45A-GA2-D
XXX-XXX
45A-GB2-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
WITH INTEGRATED FLOW CONTROLS
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
Electrical connection
KA
Square connector
KD
Square connector with light
JB
Rectangular connector
JD
Rectangular connector with light
BA
Flying leads
* Other options available, see page 353.
D
XX X- X XX
*
SOLENOID OPERATOR
®
XX X X XX
45A-XXX-D
XXX-XXX
BOTTOM PORT OPTIONS
(ORING MOUNT)
D-Sgl. oper. - All ports
F-Sgl. oper. - “A” & “B” ports
H-Dbl. oper. - All ports
J-Dbl. oper. - “A” & “B” ports
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
27,5
15,0
30,0
6,5
9,5
14,5
13,8
23,5
3,5
10,0
18,0
16,0
9,0
24,5
22,5
33,5
62,0
A
B
C
D
H
G
B
F
E
A
IN EX
IN
B
A
EX
32,5
Port size
1/8” NPTF
# 10-32 UNF
A
7.5
9.75
B
16.0
14.0
C
10.0
10.5
D
9.5
9.75
E
7.5
9.75
F
11.5
13.0
G
14.5
11.0
H
9.5
9.75
68
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
DIMENSIONS
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow (at 6 bar, ΔP=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1.8 W : (0.1 C
v
), 5.4 W : (0.15 C
v
)
100 cm
3
/min
General purpose class A, continuous duty, encapsulated
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
24 VDC (5.4 W) Energize : 6 ms De-energize : 2 ms
120/60 Energize : 3-8 ms De-energize : 2-7 ms
TECHNICAL DATA
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal (between solenoid and valve body) : 16402. • Valve cover plate with flow controls : N-45002.
• BSPP threads. • High flow up to 0.23 C
v
, according to wattage and high flow Mod. • NAMUR interface - 45A-FA1DXXX-XXX and
required NAMUR adapter kit: N-45028-03 (for 3-way operation) - N-45028-04 (for 4-way operation).
Spare parts :
Options :
Ø 3,4
Dimensions shown are metric (mm)
69
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
Function Port size Flow (Max) Individual mounting Series
4/2 #10-32 - 1/8” 0.13 C
v
sub-base
non”plug-in”
1. Balanced poppet, immune to variations of
pressure.
2. Short stroke with high flow.
3. The patented solenoid develops high shifting
forces.
4. Powerful return spring.
5. Manual operator standard on all valves.
6. Burn-out proof solenoid on AC service.
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
Port size
Valve less base
1/8” NPTF base
#10-32 UNF base
Single operator
45A-L00-D
XXX-XXX
45A-LAA-D
XXX-XXX
45A-LBA-D
XXX-XXX
Double operator
(Minimum DC wattage 5,4W)
45A-N00-D
XXX-XXX
45A-NAA-D
XXX-XXX
45A-NBA-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
Port size
Valve less base
1/8” NPTF base
#10-32 UNF base
Single operator
45A-L00-D
XXX-XXX
45A-LAB-D
XXX-XXX
45A-LBB-D
XXX-XXX
Double operator
(Minimum DC wattage 5,4W)
45A-N00-D
XXX-XXX
45A-NAB-D
XXX-XXX
45A-NBB-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
WITH INTEGRATED FLOW CONTROLS
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
Electrical connection
KA
Square connector
KD
Square connector with light
BA
Flying leads
* Other options available, see page 353.
D
XX X- X XX
*
SOLENOID OPERATOR
®
XX X X XX
45A-LAA-D
XXX-XXX
OPTIONS
Substitute “J” for 1/8” bottom cylinder ports
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
33
~24.5
A
IN
EA EB
B
C
L
EB
IN
EA
A
EA
IN
EB
B
A
A B
7,0
50
13,0
D
CC
15,1
64,0
32,0
4,0
14,5
5,0
50,0
79,1
16,0
32,0
25,0
12,0
24,0
21,5
B
6,5
9,0
A
Port size
1/8” NPTF
# 10-32 UNF
A
16.0
12.0
B
8.0
6.0
C
13.0
15.0
D
8.0
10.0
OPTIONAL PRESSURE
SENSING PORT
1/8” NPTF OPTIONAL
BOTTOM CYLINDER PORTS
4.5 DIA. (2) places
70
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
DIMENSIONS
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow (at 6 bar, ΔP=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1.8 W : (0.11 C
v
), 5.4 W : (0.13 C
v
)
100 cm
3
/min
General purpose class A, continuous duty, encapsulated
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
24 VDC (5.4 W) Energize : 6 ms De-energize : 2 ms
120/60 Energize : 3-8 ms De-energize : 2-7 ms
TECHNICAL DATA
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Flow control : N-45018.
• BSPP threads. • High flow up to 0.20 C
v
, according to wattage and high flow mod.
Spare parts :
Options :
Dimensions shown are metric (mm)
71
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
Function Port size Flow (Max) Manifold mounting Series
4/2 # 10-32 - 1/8” 0.20 C
v
stacking
1. Balanced poppet, immune to variations of
pressure.
2. Short stroke with high flow.
3. The patented solenoid develops high shifting
forces.
4. Powerful return spring.
5. Manual operator standard on all valves.
6. Burn-out proof solenoid on AC service.
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
Port size
1/8” NPTF
# 10-32 UNF
Single operator
45A-SA1-D
XXX-XXX
45A-SB1-D
XXX-XXX
Double operator
(Minimum DC wattage 5,4W)
45A-TA1-D
XXX-XXX
45A-TB1-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
Port size
1/8” NPTF
# 10-32 UNF
Single operator
45A-SA2-D
XXX-XXX
45A-SB2-D
XXX-XXX
Double operator
45A-TA2-D
XXX-XXX
45A-TB2-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
WITH INTEGRATED FLOW CONTROLS
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
Electrical connection
KA
Square connector
KD
Square connector with light
BA
Flying leads
* Other options available, see page 353.
End plate kit required (Port size 1/4” NPTF) : M-45001-01.
D
XX X- X XX
*
SOLENOID OPERATOR
®
XX X X XX
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
32,5
EX
EX
IN
IN
AB
AB
AB
A
B
EX
EX
IN
IN
54,0
62,5
44,0
49,0
17,0
16,0
9,5
9,95
15,5
62,5
19,2
(± 0,1)
12,0 ± 0,2
7,0 ± 0,2
9,5
7,5
8,0
18,5
39,0
4,0
16,0
4 × Ø 5,3
# 10-32 UNF
CYLINDER PORTS
1/8” NPTF CYLINDER
PORTS
1/4” IN & EXH. NPTF
72
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
DIMENSIONS
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow (at 6 bar, ΔP=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1.8 W : (0.14 C
v
), 5.4 W : (0.2 C
v
)
100 cm
3
/min
General purpose class A, continuous duty, encapsulated
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
24 VDC (5.4 W) Energize : 6 ms De-energize : 2 ms
120/60 Energize : 3-8 ms De-energize : 2-7 ms
TECHNICAL DATA
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal (between solenoid and valve body) : 16402. • Seal between valves : 16422. • Tie-rod (x2) : 19813.
• Valve cover plate with flow controls : N-45004.
• Inlet & exhaust isolator : N-45005. Inlet isolator : N-45006. Exhaust isolator : N-45007
• BSPP threads. • High flow up to 0.3 C
v
, according to wattage and high flow mod.
Spare parts :
Options :
Dimensions shown are metric (mm)
73
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
Function Port size Flow (Max) Manifold mounting Series
4/2 # 10-32 - 1/8” 0.11 C
v
sub-base
non”plug-in”
1. Balanced poppet, immune to variations of
pressure.
2. Short stroke with high flow.
3. The patented solenoid develops high shifting
forces.
4. Powerful return spring.
5. Manual operator standard on all valves.
6. Burn-out proof solenoid on AC service.
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
Port size
Valve less base
1/8” NPTF base
# 10-32 UNF base
Single operator
45A-L00-D
XXX-XXX
45A-LAC-D
XXX-XXX
45A-LBC-D
XXX-XXX
Double operator
(Minimum DC wattage 5.4W)
45A-N00-D
XXX-XXX
45A-NAC-D
XXX-XXX
45A-NBC-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
Port size
Valve less base
1/8” NPTF base
# 10-32 UNF base
Single operator
45A-L00-D
XXX-XXX
45A-LAD-D
XXX-XXX
45A-LBD-D
XXX-XXX
Double operator
(Minimum DC wattage 5.4W)
45A-N00-D
XXX-XXX
45A-NAD-D
XXX-XXX
45A-NBD-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
WITH INTEGRATED FLOW CONTROLS
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
Electrical connection
KA
Square connector
KD
Square connector with light
BA
Flying leads
* Other options available, see page 353.
End plate kit required (Port size 1/4” NPTF) : M-45008-01
D
XX X- X XX
*
SOLENOID OPERATOR
®
XX X X XX
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
AA
B B
IN
9,0
2,5
9,75
5,2
18,9
71,1
10,0
20,5
51,0
17,5
8,5
4,0
8,0
8,0
4,0
62,5
20,10 ±0,1
33
IN
EX
29,0
13,5
13,7
17,3
19,0
# 10-32 UNF
PORTS CYLINDER
1/8” NPTF
CYLINDER PORTS
OPTIONAL 1/8” NPTF
BOTTOM INLET
1/4” NPTF INLET & EXHAUST
PORTS BOTH ENDS
Ø 5,3 MTG. SLOT
OPTIONAL
ISOLATOR
74
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
DIMENSIONS
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow (at 6 bar, ΔP=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1.8 W : (0.09 C
v
), 5.4 W : (0.11 C
v
)
100 cm
3
/min
General purpose class A, continuous duty, encapsulated
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
24 VDC (5.4 W) Energize : 6 ms De-energize : 2 ms
120/60 Energize : 3-8 ms De-energize : 2-7 ms
TECHNICAL DATA
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455.
• Tie-rod (x2) : 19753. • Side cover plate with flow controls : N-45016.
• Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.
• BSPP threads. • High flow up to 0.18 C
v
, according to wattage and high flow Mod. • Bottom inlet : specify Mod. 0210.
Spare parts :
Options :
Dimensions shown are metric (mm)
75
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
Function Port size Flow (Max) Manifold mounting Series
4/2 # 10-32 - 1/8” 0.11 C
v
sub-base with
pressure
regulators
1. Balanced poppet, immune to variations of
pressure.
2. Short stroke with high flow.
3. The patented solenoid develops high shifting
forces.
4. Powerful return spring.
5. Manual operator standard on all valves.
6. Burn-out proof solenoid on AC service.
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
Port size
Valve less base
1/8” NPTF base
# 10-32 UNF base
Single operator
45A-L00-D
XXX-XXX
45A-LAJ-D
XXX-XXX
45A-LBJ-D
XXX-XXX
Double operator
(Minimum DC wattage 5,4W)
45A-N00-D
XXX-XXX
45A-NAJ-D
XXX-XXX
45A-NBJ-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
Electrical connection
KA
Square connector
KD
Square connector with light
BA
Flying leads
* Other options available, see page 353.
End plate kit required (Port size 1/4” NPTF) : M-45008-01.
Options (with gauge port) : Single operator : replace L by M.
Double operator : replace N by P.
D
XX X- X XX
*
SOLENOID OPERATOR
®
XX X X XX
(“J” is for Adj. knob)
45A-XXJ-D
XXX-XXX
REGULATOR OPTIONS
Replace with “E” for slotted stem
Replace with “G” for locking slotted stem
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
AA
B B
IN
9,0 ± 0,2
2,5
9,75
5,2
18,9
71,1
13,5
10,0
20,5
51,0
17,5
8,5
4,0
8,0
8,0
4,0
62,5
20,10 ±0,1
33,0
IN
EX
29,0
13,5
14,0
Ø 15,5
13,7
17,3
19,0
# 10-32 UNF
PORTS CYLINDER
OPTIONAL 1/8”
NPTF BOTTOM
INLET
1/8” NPTF CYLINDER
PORTS
1/4” NPTF INLET & EXHAUST
PORTS BOTH ENDS
OPTIONAL
GAGE PORT
Ø 5,3 MTG. SLOT
OPTIONAL
ISOLATOR
76
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
DIMENSIONS
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow (at 6 bar, ΔP=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1.8 W : (0.09 C
v
), 5.4 W : (0.11 C
v
)
100 cm
3
/min
General purpose class A, continuous duty, encapsulated
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
24 VDC (5.4 W) Energize : 6 ms De-energize : 2 ms
120/60 Energize : 3-8 ms De-energize : 2-7 ms
TECHNICAL DATA
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455.
• Tie-rod (x2) : 19753. • Pressure regulator : 45A-00R (Adj. Knob), 45A-00L (Slotted Stem), 45A-00M (Locking Slotted Stem).
• Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.
• BSPP threads. • High flow up to 0.18 C
v
, according to wattage and high flow mod. • Bottom inlet : specify Mod. 0210.
Spare parts :
Options :
13,4 LOCKING
KNOB
102,1 REGULATOR W/ SLOTTED STEM
Dimensions shown are metric (mm)
77
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
Function Port size Flow (Max) Manifold mounting Series
4/2 # 10-32 - 1/8” 0.11 C
v
sub-base with
pressure
regulators and
flow controls
1. Balanced poppet, immune to variations of
pressure.
2. Short stroke with high flow.
3. The patented solenoid develops high shifting
forces.
4. Powerful return spring.
5. Manual operator standard on all valves.
6. Burn-out proof solenoid on AC service.
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
Port size
Valve less base
1/8” NPTF base
# 10-32 UNF base
Single operator
45A-L00-D
XXX-XXX
45A-LAK-D
XXX-XXX
45A-LBK-D
XXX-XXX
Double operator
(Minimum DC wattage 5,4W)
45A-N00-D
XXX-XXX
45A-NAK-D
XXX-XXX
45A-NBK-D
XXX-XXX
AB
AB
EXH IN
AB
AB
EXH IN
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
Electrical connection
KA
Square connector
KD
Square connectorwith light
BA
Flying leads
* Other options available, see page 353.
End plate kit required (Port size 1/4” NPTF) : M-45008-01.
Options (with gauge port) : Single operator : replace L by M
Double operator : replace N by P.
D
XX X- X XX
*
SOLENOID OPERATOR
®
XX X X XX
45A-XXK-D
XXX-XXX
F.C. OPTIONS
REGULATOR AND
Replace with “F” for slotted stem and F.C.
(“K” option is for Adj. knob and F.C.)
Replace with “H” for locking slotted stem and F.C.
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
AA
B B
IN
9,0 ± 0,2
2,5
9,75
5,2
18,9
71,1
13,5
10,0
20,5
51,0
17,5
8,5
4,0
8,0
8,0
4,0
62,5
20,10 ±0,1
33,0
IN
EX
29,0
13,5
14,0
Ø 15,5
13,7
17,3
19,0
LOCK
15,5
# 10-32 UNF
CYLINDER PORTS
1/8” NPTF
CYLINDER PORTS
6,0 LOCKING STEM
ADJ. LOCKING KNOB
OPTIONAL
1/8” NPTF
BOTTOM INLET
1/4” NPTF INLET &
EXHAUST PORTS BOTH
ENDS
OPTIONAL
GAGE PORT
Ø 5,3 MTG. SLOT
102,1 REGULATOR W/SLOTTED STEM
OPTIONAL
ISOLATOR
78
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Series
45
DIMENSIONS
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow (at 6 bar, ΔP=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1.8 W : (0.09 C
v
), 5.4 W : (0.11 C
v
)
100 cm
3
/min
General purpose class A, continuous duty, encapsulated
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
24 VDC (5.4 W) Energize : 6 ms De-energize : 2 ms
120/60 Energize : 3-8 ms De-energize : 2-7 ms
TECHNICAL DATA
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455.
• Tie-rod (x2) : 19753. • Pressure regulator with flow controls : 45A-00N (Slotted Stem), 45A-00P (Locking Slotted Stem),
45A-00S(Adj. Knob). • Inlet & exhaust isolator : N-45008. • Inlet isolator : N-45009. • Exhaust isolator : N-45010.
• BSPP threads. • High flow up to 0.18 C
v
, according to wattage and high flow Mod. • Bottom inlet : specify Mod. 0210.
Spare parts :
Options :
13,4 LOCKING KNOB
Dimensions shown are metric (mm)
Series
35-45
Intrinsically Safe Valves
HOW TO ORDER
BODY TYPE
Inline
A
Individual Inline
D
Indiv. Inline w/2
Manifold Mount Ports
Manifold
E
Manifold Body (N.C. Only)
G
Manifold Body w/Gage Port
(N.C. Only)
PORT SIZE
O
Manifold Body Only
B
#10-32 UNF (Inline Only)
D
M5 (Inline Only)
VALVE FUNCTION/MANIFOLD TYPE
O
Manifold Body Only
B
3 way N.C. Only (Inline)
Note : there is no manifold base for the 35 series.
The manifold valve can only mount to a circuit bar, see note below
NOTE : For valves mounted to a circuit bar reference MAC circuit bar Catalog for ordering info.
For the 35 series circuit bar, use MOD FM01 after circuit bar part number.
35A - X X X - (DXXX - XXX) - FM
BODY
OPTIONS
SOLENOID
OPTIONS
BODY TYPE
Inline
A
4 Port Body
B
5 Port Body
D
4 Port Body “O” Ring
Mount -All Bottom Ports
E
5 Port Body “O” Ring
Mount -3 Bottom Ports
Inlet and Cylinders
F
4 Port Body “O” Ring
Mount-Bottom Cylinder
Ports Only
Base Mount
O
For Base Only - No Valve
L
Base Mount Body
M
Base Mount Body with Gage Port
PORT SIZE
O
Manifold Body Only
A
1/8" NPT
B
#10-32 UNF
C
1/8" BSPPL
D
M5 (Metric)
F
#10-32 UNF Bottom Ports
G
M5 Bottom Ports
H
“O” Ring Mount Ports
J
1/8" NPT Bottom Ports
K
1/8" BSPPL Bottom Ports
VALVE FUNCTION/MANIFOLD TYPE
Inline
1
No Flow Controls
Bases - Regulators
O
Valve Only - No Base
A
Individual Base
C
Manifold Base
E
Manifold w/Regulator w/Slotted Stem
G
Manifold w/Regulator w/Locking Slotted Stem
J
Manifold w/Regulator w/Locking Knob
45A - X X X - (DXXX - XXX) - FM
BODY
OPTIONS
SOLENOID
OPTIONS
MANIFOLD MOUNT ACCESSORIES
M-45008-01
End Plate Kit
16455
Pressure Seal Between Manifold
19753
Tie Rod
N-45008
Isolator Kit - Inlet and Exhaust
N-45009
Isolator Kit - Inlet only
N-45010
Isolator Kit - Exhaust only
N-45015
End Cover Plate - Plain
N-45016
End Cover Plate w/Flow Controls
N-45017
Flow Control Needle Assembly
VOLTAGE
FR
12VDC (0.6 W)
FS
24VDC (0.6 W)
LEAD LENGTH
A
18" Leads
B
24" Leads
C
36" Leads
D
48" Leads
E
72" Leads
J*
6" Leads
*Use “J” for external plug-in connectors
MANUAL OPERATOR
0
No operator
1
Non-locking Recessed
2
Locking Recessed
3
Non-locking Extended
4
Locking Extended
D - X X X - X X X - FM
SOLENOID OPTIONS
ELECTRICAL CONNECTION
BA
Grommet
CA
Conduit 1/2" NPS†
CM
Metal
Conduit 1/2" NPS†
CN
Metal Conduit w/grd. 1/2" NPS†
External Plug-in
FM
Plug-in (For ECD & ECE Bar)
JB
Rectangular Plug-in†
JM
Rectangular Male only†
KA
Mini Plug-in
KJ
Mini Plug-in Male only
TA
Dual Tabs (.110) Plain
TJ
Dual Tabs (.110) Plain
† Available on individual valves and
circuit bars.
334
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
OPTIONS
O p t i o n s
Codification table for voltages / Wire length / Manual operators / Electrical connections
- Solenoid valves 35, 45 and 82 Series
- D XX X - X XX
1 2 3 4
VALVE CODE
®
OPTIONS AVAILABLE FOR
353
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
OPTIONS
1. VOLTAGE
- D XX X - X XX
VOLTAGE
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
AD
24/60
AE
200/60
AF
240/50
AG
100/50, 100/60, 110/60
DA
24 VDC (5.4 W)
DB
12 VDC (5.4 W)
DC
12 VDC (7.5 W)
DD
24 VDC (7.3 W)
DE
12 VDC (12.7 W) - CLSFonly
DF
24 VDC (12.7 W) - CLSF only
DK
110 VDC (4.7 W)
DL
64 VDC (6 W)
DM
36 VDC (5.3 W)
DN
6 VDC (6 W)
DP
48 VDC (5.8 W)
DU
24 VDC (6 W)
EA
12 VDC (6 W)
FA
12 VDC (1.8 W)
FB
24 VDC (1.8 W)
FE
12 VDC (2.4 W)
FF
24 VDC (2.4 W)
2. WIRE LENGTH
- D XX X - X XX
WIRE LENGTH
A
18”
B
24”
C
36”
D
48”
E
72”
F
96”
J
For external plug-in connector (“J”, “K” & “T” type electrical connection)
P
For plug-in valves (82 Series only)
354
Consult “Precautions” page 356 before use, installation or service of MAC Valves.
363
O P T I ONS
3. MANUAL OPERATOR
- D XX X - X XX MANUAL OPERATOR
0 No operator
1 Non-locking recessed
2 Locking recessed
3 Non-locking extended
4 Locking extended
4. ELECTRICAL CONNECTION
- D XX X - X XX ELECTRICAL CONNECTION
BA Flying leads
BK BA with protection diode
BL BA with protection varistor (M.O.V.)
** CA 1/2" NPS conduit
** CM 1/2" NPS metal conduit
** CN 1/2" NPS metal conduit w/ground
** JB Rectangular connector
** JD Rectangular connector with light
** JM Rectangular connector, male only
KA Square connector
KB Square connector with protection diode
KC Square connector with protection varistor (M.O.V.)
KD Square connector with light
KE Square connector with light and protection diode
KF Square connector with light and protection varistor (M.O.V.)
KG Square connector with LED light & diode
KJ Square connector (male only)
KK Square connector with protection diode (male only)
KL Square connector with protection varistor (male only) (M.O.V.)
TA Dual tabs
TB TA with protection diode
TD TA with light
TE TA with light and protection diode
TJ Dual tabs (male only)
TK TJ with protection diode
TM TJ with light
TN TJ with light and protection diode
DA* Plug-in connector
DK* DA with protection diode
DL* DA with protection varistor (M.O.V.)
FM Plug-in
FN Plug-in with diode
FP Plug-in with M.O.V.
* To be used with 82 Series only
** Inline valves only for 35 & 45 series. No restrictions for 82 series.
Consult “Precautions” page 364 before use, installation or service of MAC Valves
O p t i o n s